Attaching Neopor insulation blocks to the foundation exterior

Neopor insulation blocks are fitted and screwed onto furring strips. After the attachment , gaps will be filled with expanding foam insulation. The application of these blocks will complete the envelope of insulation running under the slab and footing, then up the exterior of the poured concrete foundation. The foundation and slab are completely insulated from ground contact and thermal bridging.

Furring strips

Furring strips will provide a backing surface and a ventilation gap between the SIPs and the exterior clapboard. The strips are glued directly to the SIPs to provide ensure strong attachment to the house. 30lb. felt paper will go over the strips, followed by the clapboard.